网上赌场网址多少

Analysis of common faults of spiral swing cylinder

hit count: Updated: 19/07/10 15:47:07 Source: avervenus.com [ close ] share:
    During the use of the spiral swing cylinder, the following four failures often occur due to improper operation. Let us understand the causes and solutions of the failures:
    1. Spiral swing oil cylinder leaking oil
    1. Shaft oil leakage: Because the oil seal and the output shaft are in constant friction during the daily use of the oil cylinder, the contact surface between the oil seal and the shaft will inevitably be worn. Exceeding a certain limit will cause the oil seal to lose its sealing effect and cause oil leakage .
    Solution: The oil seal needs to be replaced. If the output shaft is worn out, the output shaft must be replaced at the same time.
    2. Oil leakage at the cover: The "O" ring under the cover is crushed or aged and loses the sealing effect. The probability of this situation is very low.
    The solution: Just replace the "O" ring.
    3. Oil leakage between the cylinder gap: The "O" ring between the cylinder shell and the front side plate, or the front side plate and the stator body, or the stator body and the rear side plate is aging or crushed.
    The solution: Just replace the "O" ring.
    Second, the spiral swing oil cylinder runs weakly
    1. The stator body pairing is too loose: As the oil cylinder is in operation, all parts in the oil cylinder are in a state of friction with each other. If the oil quality of the hydraulic oil in the system is too poor, it will accelerate the wear of the internal parts of the oil cylinder. When the wear of the needle in the stator body exceeds a certain limit, the internal gap of the stator body pairing will become larger, the normal oil sealing effect cannot be achieved, and excessive leakage in the oil cylinder will be caused. The symptom shown is that the cylinder runs normally under no load, but the sound will be slightly louder than normal, and it will be weak or run slowly under load.
    Solution: Replace the needle.
    2. Wear between output shaft and casing: The main cause of this failure is the impure hydraulic oil, which contains impurities, which causes the grooves inside the casing to be worn out, leading to increased internal leakage in the cylinder, which causes the cylinder to become weak.
    The solution: replace the shell or the entire pair.